admin

Lifetherm + Leoni mobil

Designed for use in the initial care of babies with ventilation and warming therapy unit.

Warming therapy:
– Effective, fast-response radiant heater
– Conductive heat by a heated gel mattress
– Electric height adjustment from both sides of the bed
– Smooth electric bed tilting at the press of a button
– Panels can all be folded down
– Wide range of accessories and optional shelves

Ventilation:
– Integrated ventilator: Leoni mobil*
– Ventilation of premature infants, neonates and children weighing up to 30 kg
– Ventilation modes: Leoni mobil: CPAP, nCPAP, IPPV, nIPPV, SIMV, SIPPV and PSV
– Oxygen/air blender (21 % – 100 %)
– Integrated oxygen monitor
– Pressure waves on graphic display
– Automatic adjustment of alarm limits to match ventilation pressure

*Optional

Posted by admin in Neonatology, 0 comments

Lifetherm Resuscitation Units

A resuscitation unit with a lot of different options for optimal adjustment to suit the application as well as the needs of the baby and operating staff.

  • Swiveling, fast-response radiant heater with integrated examination lamp
  • Conductive heat by a heated gel mattress
  • Quiet, electric height adjustment (up to 30 cm) with footswitch control on both sides of the bed*
  • Gentle electric bed tilting by pressing the corresponding button
  • Fold-down side panels available in various heights
  • Skin temperature control and display (accuracy ± 0.1°C)*
  • Covers available that can be opened on either side, as well as one-piece covers*
  • Trays which allow the attachment of control panels and ventilators
  • Standard rails for attaching accessories such as catheter holders, trays or suction devices*

*Optional accessory

Posted by admin in Neonatology, 0 comments

Lifetherm Warming Bed

A new generation of Warming Cradles and Reanimation Units sets standards in neonatology. Due to the completely revised design of its components, Lifetherm 2000 became a real professional for hospital use. Some details have been still better adapted to practical requirements, thus resulting in a new and modern design.

The warming bed is available without cover, with a closed cover or with a fold up cover that can be opened on both sides, and can be upgraded with extensive accessories.

The so called contact heat of the surface heater is the most effective type of heat transfer. The comfortable and soft gel-mattress will avoid pressure marks to the baby and support thermal stability of premature infants.

Posted by admin in Neonatology, 0 comments

CHARISMA

CPAP therapy in the 21st century

Charisma is a state-of-the art device for constant positive airway pressure therapy.

  • Coloured touch screen: intuitive user guidance
  • Automatic flow adjustment and adaption
  • Unique: no reservoir bag needed
  • Dynamic leakage compensation
  • Cost efficiency by low gas consumption
  • Drug nebulizer

Direct input of oxygen concentration and PEEP
Gas mixture tables, readjustment of flow and uncertainties in mask leakages are things of the past. The user enters directly PEEP and oxygen concentration. charisma verifies the ventilation accessories used and guaranties the secure compliance of the parameters set.

Dynamic compensation of leakage
Older CPAP equipment, working with Continuous-Flow- Principle, had to be adjusted manually to the gas flows offered in order to compensate variable mask leakages. When the supply of flow was too low, the set PEEP value could not be realised and the danger of alveolar collapse appeared. charisma combines the established Demand- Flow with the Continuous-Flow-Principle, readjusts the necessary flow continuously and controls the PEEP set.

Individual alarm settings
There are fundamental differences in monitoring requirements of intensive care units, outpatient departments, wards and therapy wards. charisma allows the alarm adaption to the necessities of the clinical routine. Thereby requirements of apnea, alarms of low and high pressure values and alarm volume are directly adjustable via touch screen.

Innovative monitoring of leakage according to “traffic light principle”
charisma monitors existing mask leakages without interruption and adapts the inspiration flow consecutively. According to the traffic light, leakages are displayed visually and easily comprehensible.

Posted by admin in Intensive Care Ventilation, 0 comments

ELISA 800

Until recently, there was a gap between scientific evidence and clinical practice in intensive care ventilation. Inadequate technical options and nontransparent evaluation of measurement results frequently stood in the way of the desired treatment. In many cases, the available procedures simply were not sufficient for broad, yet dependable use.

Drawing on more than 25 years of experience, Heinen + Löwenstein is now making the impossible a reality: Intensive care ventilation – simple, clear and verifiable. The simple solution adds safety, reduces training needs, and allows for the broad use of ventilation strategies. It is economical, minimizes operating errors, and gives you more time to focus on the essential.

Elisa 800 stands for simplifying complexity.

  • Powerful hardware
  • Electrical impedance tomography
  • Modular software concept
  • Expandable ventilation architecture
  • Versatile interfaces
  • Versatile option boxes
  • Intelligent cable management
  • Intelligent acoustic alarm system
  • State-of-the-art power management
  • Light sensor for day-night adjustment
  • Heliox-ready
  • Integrated ventilation protocol
Posted by admin in Intensive Care Ventilation, 0 comments

ELISA 600

Elisa 600 is an innovative standard breathing ventilator for invasive and non-invasive artificial respiration in the case of all clinical conditions, for all intensive care activities and for patients weighing 3,5 kg and more. A variety of hardware and software options allow for individual configuration to be made according to the requirements at hand, as well as providing for an artificial respiration platform that is assured a good future.

Posted by admin in Intensive Care Ventilation, 0 comments

SINUS

Sinus’ functional design is a convincing argument for users in clinics and surgeries.

But this anaesthesia apparatus has proved its worth in mobile applications-for first aid at the place of accident or during emergency transports.

Sinus can be used in conjunction with the ISO circulation system or the semi-open anaesthesia system. N2O and O2 are supplied via wall-mounted terminals, a central gas supply system, or a gas bottle stack. Special features include the integrated wall bracket, the retractable handle, the pull-out bracket for the circulation system, the lid for closing the device and four measuring tubes allowing for fine dosing during low-flow operation. SRS minimum oxygen dosing technology guarantees a very high degree of safety for the patient.

Posted by admin in Anaesthesia, 0 comments

Leon Ceiling

Of course, the ‘anaesthesia support’ Leon is also available as a unit for wall and ceiling suspension. The unit is identical with the mobile cart version.

With this option, Heinen + Löwenstein offers a further range of application in anaesthesia care thus making your work routines even more flexible.

Compose your own, individually scheduled work station on the basis of Leon. Today and for the future, you will obtain the highest possible flexibility and safety using this anaesthesia work station.

Posted by admin in Anaesthesia, 0 comments

Leon MRI

The Leon MRI has been specially developed for use in the MRI area with field strengths of up to 40 millitesla. It can be operated on 1.5 tesla and 3.0 tesla MRI systems.

Different coloured alarms and messages indicating the priority can be easily recognised due to LED lights, which are visible from all sides, also outside the MR field.

Power spectrum of the Leon MRI: Both the power spectrum and the operation of the Leon MRI, match exactly, without any restrictions, those of the already well-established LEON.

A further major logistic advantage can be found in the compatibility of the compact circuit system with the LEON plus, LEON and Leon MRI systems. The position to MRI is monitored by an integrated magnetic field strength monitor.

Posted by admin in Anaesthesia, 0 comments

ELISA

The Elisa is an intensive care ventilator for adults and children from the age of one year or a body weight of 5 kg. The device can be optionally used for ventilation of newborn patients with a body weight from 2 to 6 kg.

The all-purpose intensive care ventilator Elisa is prepared for all types of patients: Newborn (optional), child and adult. Modern microprocessor technology, precise measurement techniques and efficient technologies assure an accurate ventilation therapy and individual ventilation strategies.

Elisa provides the clinical practice orientated combination of both invasive and non-invasive ventilation in a single device. You can choose between spontaneous or controlled non-invasive ventilation strategies. The modern intensive care ventilator measures the expiration volume precisely and includes a reliable leakage compensation.

Posted by admin in Intensive Care Ventilation, 0 comments